Improvement of Hall Effect Current Transducer Metrological Performances in the Presence of Harmonic Distortion
2010
The performance of Hall effect current transducers (HECTs), under distorted waveform conditions, is usually characterized by means of a frequency response test. In this paper, it was investigated if frequency response is able to correctly evaluate the ratio and the phase errors under distorted conditions. Two HECTs, with the accuracy class level of 1% and 0.5%, respectively, were experimentally characterized under two conditions: 1) sinusoidal excitation with frequencies ranging from 50 to 750 Hz, which is the well-known frequency response test, and 2) nonsinusoidal excitation using fundamental frequency and one harmonic with adjusted amplitude and phase shift. It was found that ratio and p…
Characterization of clamp-on current transformers under nonsinusoidal conditions
2009
This paper reports the performance of clamp-on current transformers under nonsinusoidal conditions. A set of experimental measurements helped to determine the ratio and the phase errors under two conditions: 1) sinusoidal excitation with frequencies from 45 to 1000 Hz and 2) nonsinusoidal excitation using the fundamental frequency and one harmonic, with adjusted phase shift. It was found that ratio and phase errors are affected by the phase angle between the harmonic and the fundamental and the harmonic amplitude. The effects of conductor location in the current transformer's window and of the air-gap width were also investigated. It was concluded that harmonic phase and ratio errors measur…
A novel approach to current transformer characterization in the presence of harmonic distortion
2009
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…
Quasi-digital conversion for resistive devices: application in GMR-based IC current sensors
2013
Resistive devices, including sensors, are used in a huge range of applications within different scenarios. When a complete system is considered, a quasi-digital output is often recommendable. If the conversion is operated at device level, some problems such as noise disturbs, insertion losses and so on, can be reduced. In this work, we describe a resistance-tofrequency (R-f) converter with a suggested application in low current monitoring by means of GiantMagnetoResistance (GMR) sensors. Specific devices have been designed and microfabricated. The system has been tested by means of discrete components with a PCB. The complete microsystem monolithic integration in a standard CMOS technology …